Description
The conductive electrodes of the EE-21...F/EE-22...F series enable the monitoring of conductive liquids within the hazardous area Zone 0 (Category 1).
Technical Data
Properties
- connection
- Edelstahl (1.4571)
- Protection class
- IP 65
- Ex-protection
- TÜV 02 ATEX 1796 X
- Ex protection type
- II 1 G Ex ia IIC T6 bzw. Ex ia IIB T6 / II ½ G Ex ia IIC T6 bzw. Ex ia IIB T6
- connection thread
- G1", G1¼", G1½”
- Coating length
- voll=ganzer Stab (10 mm am Stabende sind blank) teil =ca. 250 mm von oben
- Rod diameter
- 4 oder 6 mm
- rod length
- max. 6 m
- Operating pressure media side
- max. 40 bar
- Maximum permissible electrical connection values
- Stromkreis in Zündschutzart Eigensicherheit Ex ia IIC/IIB
- Connection values
- Ui 15V | Li 10 mA | Pi 100 mW
- Internal inductances / capacitances
- vernachlässigbar klein
- Spacer
- ab Länge > 1000 mm je 1000 mm 1 Abstandshalter
Operating temperature
- Category 1 Class T6...T1
- 60 °C
- Category 2 Class T6
- Medien & Umgebung 80 °C
- Category 2 Class T5
- Medien & Umgebung 95°C
- Category 2 Class T4
- Medien 130°C, Umgebung 100°C
- Category 2 Class T3...T1
- Medien 150°C, Umgebung 100 °C
Material
- Cable entry EE-21
- Edelstahl (1.4571)
- Cable entry EE-22
- PVDF
- Electrode body material
- Edelstahl (1.4571)
- Seal (head)
- Viton
- Seal (media side)
- Viton / PTFE
- Potential equalisation conductor connection
- Edelstahl (1.4571)
- Material electrode rods
- Edelstahl (1.4571), Hastelloy B, Hastelloy C, Tantal
- material coating
- PTFE
EE-21F | EE-22F configuration
Your Configuration
- Basename
- EE2
- Typ
- Elektrodenanzahl
- Anschlussgewinde
- Stabmaterial
- Stabdurchmesser
- Beschichtung
- Kabelbruchwiderstand
- Sicherheitsfunktion
- Stablänge
Further product information
These are also approved by "DIBt" as overfill prevention devices for water-polluting and flammable liquids. The screw connection of the EE-21 ...F / EE-22 ...F is made of stainless steel 1.4571. The electrode rods are made of stainless steel 1.4571, Hastelloy B, Hastelloy C or tantalum. This makes the conductive electrodes EE-21F / EE-22F also suitable for use with highly aggressive media. The conductive electrodes of the EE-21F / EE-22F type series are intended for installation inside vessels whose gas space inside the vessel may be classified as Ex zone 0 (category 1).
- Overfill protection Z-65.13-405
- EC type examination certificate TÜV 02 ATEX 1796 X
- Fully applicable within Ex-Zone 0 (Category 1)
- Also with cable tail
- Up to 4 limit levels can be detected with one electrode
- G 1" threaded connection possible (for one limit level)
- Level detection of conductive gaseous media (ammonia water, fermentation/digestion solutions)
- Interference-free measurement Boundary layer measurement conductive / non-conductive
System structure
The conductive electrodes EE-21F / EE-22F can be used in conjunction with our Ex-i electrode relays type ER-14... can be used. The type EE-21F for category 1 is to be mounted in connection with the flameproof cable bushing FK-100. If the conductive electrodes are installed on vessels which must be protected against ignition hazards caused by lightning according to TRbF 20 Section/ Chapter 12, the requirements of TRbF 20 Section/ Chapter 12 must be observed during installation. The BL-100 lightning protection device must be used.
Note: Only for connection to certified intrinsically safe circuits in type of protection intrinsic safety Ex ia IIC/IIB! The EC type examination certificate TÜV 02 ATEX 1796 X must be observed!